GHL level sensors (optical and float versions) and the built-in or expansion card inputs on the GHL ProfiLux controllers used for monitoring and managing water levels for tasks such as Auto Top-Off (ATO), automatic water changes (AWC), and leak detection.
Key Components
-
ProfiLux Controller (4 or 4e): The central unit of the GHL system, which features integrated connections for various sensors, including level sensors. The ProfiLux 4 has 4 level sensor inputs built-in, expandable to a maximum of 16.
-
GHL Level Sensors: These are the physical components that detect the water level.
-
Optical Level Sensor: Used for horizontal mounting, ideal for precise high/low-level detection in sumps or reservoirs.
-
Floater Level Sensor: Used for vertical mounting, typically for applications like auto top-off or monitoring reservoir levels.
-
Expansion Modules: If more than the standard number of level sensor inputs are needed, an expansion card like the PLM-4 Level or PLM-pH/Redox-2Level can be added to the ProfiLux controller or an expansion box.
Functionality
The GHL system uses the data from these level sensors to perform a variety of automated and safety functions:
-
Auto Top-Off (ATO): Automatically adding fresh water to compensate for evaporation, maintaining a consistent water level.
-
Automatic Water Changes (AWC): Defining minimum and maximum water levels to automate the process of draining and refilling the aquarium.
-
Leak Detection: Placing sensors in critical areas (e.g., on the floor under the tank or sump) to immediately detect leaks and trigger alarms or shut down pumps.
-
Pump Control: The controller can turn pumps on or off based on specific water levels, for instance, to protect a pump from running dry or to prevent overflow.
The setup and programming of these functions are done via the GHL Connect app or the integrated web interface, designed for user-friendly operation without requiring programming skills.
GHL does not sell a standalone level module that operates independently of their main controller or dosing systems; the level control is an integrated feature of the ProfiLux line, utilizing external sensors as accessories.